Groundwater Sampling


The primary methods for groundwater sample acquisition are done by utilizing the SP-15, SP-16 sampler or the Groundwater Profiler. The samples can be obtained in a number of ways. The most common method utilizes polyethylene or Teflon-tubing and a Tubing Bottom Check Valve. The check valve is attached to one end of the tubing and inserted down the casing until it is immersed in groundwater. Water is pumped through the tubing to the ground surface by oscillating the tubing up and down, or pumping through a peristaltic pump . Collect the sample by withdrawing and draining the tubing.

The Groundwater Profiler is able to conduct vertical profiling of groundwater quality from a discrete interval using 6 in. or 12 in. (152 or 305 mm) screens. Profiling can be conducted to determine vertical distribution of contaminants, especially in sandy or coarser grained aquifers, as the tool is advanced incrementally into the formation. There's no need to retract the Profiler after each sample is collected. Purging water through the Profiler with a peristaltic pump as it is advanced minimized clogging of the screen.

The Profiler allows the user to not only obtain high integrity, discrete interval samples over a depth profile, but also lets the user conduct hydraulic conductivity tests at each sampling depth (i.e. slug tests) to determine the most probable contaminant flow paths.

Rather than small "port holes" that may be prone to clogging, the larger screen area of this tool provides a much greater surface area for the flow of groundwater into the system. This tool is 1.375 in. (35 mm) in diameter and can be telescoped through Geoprobe's 2.125-in. (54 mm) probe rods. Development of the screen can also be conducted at each sampling depth to lower turbidity when required. Bottom up (positive pressure) grouting can be conducted when an expendable point is used.

Groundwater Profiler individual parts, expendable points, and O-rings may be purchased separately as needed. Complete kits are available with either a 6 in. or 12 in. screen interval and either a solid or expendable drive point option.


 

 

ZEBRA News.

Join Us at RemTEC '09:
Remediation Tech Summit
March 3-5, 2009
Marriott Atlanta Marquis
265 Peachtree Center Avenue
Atlanta, GA 30303

Join us at the Battelle Bioremediation Symposium:
Baltimore, MD
May 5-9, 2009
Come by and say hello!

ZEBRA On The Move:
Our Raleigh has moved
4205 Newington Hills Way
Cary, NC 27513
919-424-6122

ZEBRA VACMASTER 1000: ZEBRA Environmental has just added a VACMASTER 1000 to its fleet.

Read More About It